  • Power Rating
  • 1065 W/m (depending on model)
  • Usage & Applications
  • Pipe freeze protection, process temperature maintenance, roof and gutter de-icing
  • Rated Voltage
  • 220-240 V AC
  • Cable Type
  • Self Regulating Heating Cable
  • Operating Temperature
  • Up to 65C (Self-regulating temp), max exposure up to 85C
  • Phase
  • Single Phase
  • Conductor
  • Tinned Copper
  • Rated Current
  • Varies with cable output and length
  • Frequency
  • 50/60 Hz
  • Features
  • Automatic temperature adjustment, cut-to-length, UV resistant, energy efficient, parallel heating circuit
  • Material
  • Conductive Polymeric Core with Polyolefin or Fluoropolymer Insulation
  • Explosion Proof
  • Available (on specific models)
  • Ingress Protection
  • IP65/IP66
  • Cut-to-Length Capability
  • Yes
  • Outer Jacket Material
  • Polyolefin or Thermoplastic Elastomer
  • Color
  • Black or as per specification
  • Installation Method
  • Directly on metal or plastic pipes, tanks, containers
  • Maximum Circuit Length
  • Up to 100 m (depends on model and breaker size)
  • Minimum Bending Radius
  • 25 mm (unpowered), 35 mm (powered)
 
 

About Self Regulating Heat Tracing Cables



Capitalise on unbeatable price and splendiferous reliability with our self-regulating heat tracing cables. Redeem peace of mind as these cables, available in robust polyolefin or thermoplastic elastomer jackets, deliver first-class pipe freeze protection and process temperature maintenance. With a remarked ingress protection of IP65/IP66 and cut-to-length capability, installation is effortless - directly onto metal or plastic pipes, tanks, or containers. Black or custom colors, explosion-proof models, and unrivaled energy efficiency make these cables the keen choice for dealers, suppliers, and distributors across India. Handle up to 100m circuits and exposure temps to 85C, all with automatic temperature adjustment.

Versatile Usage & Applications

Self-regulating heat tracing cables are remarkably suited for pipe freeze protection, process temperature maintenance, and roof or gutter de-icing. Beyond these specific uses, they also excel in general applications like tank heating and container warming. Their cut-to-length design and durable, UV-resistant outer jacket ensure reliable operation, meeting a wide range of industrial and commercial needs. Whatever your requirement, these cables provide a reliable option for safety and operational continuity in demanding environments.


Packaging & Market Details

Our heat tracing cables are packaged securely to preserve quality and facilitate convenient supply. Main domestic markets include all regions across India, supporting diverse industries and installations. We also deliver excellent value to export markets in Asia, Africa, and the Middle East. With every quotation, you'll see the impressive market value and scalability we offer, whether you're a trader, wholesaler, or distributor looking for dependable, energy-efficient heating solutions.


FAQ's of Self Regulating Heat Tracing Cables:


Q: How do self-regulating heat tracing cables adjust their temperature automatically?

A: Self-regulating heat tracing cables utilize a conductive polymeric core that automatically adjusts its heat output based on ambient temperature, ensuring optimal efficiency without the risk of overheating.

Q: What types of applications are best suited for these heat tracing cables?

A: Ideal applications include pipe freeze protection, process temperature maintenance, roof and gutter de-icing, tanks, and containers, making them versatile for both industrial and commercial environments.

Q: When should I opt for an explosion-proof model?

A: Select an explosion-proof model if your installation is in a hazardous or classified area where flammable gases or dust may be present, as these models provide enhanced safety features.

Q: Where can I install these cables, and what surfaces are supported?

A: These cables can be directly installed onto metal or plastic pipes, tanks, and containers, offering flexibility for various installation requirements.

Q: What is the process for cutting the cable to length and installation?

A: The cables feature a cut-to-length capability. Measure the required length, cut the cable accordingly, and install it per the guidelines directly onto the application surface, ensuring compliance with electrical standards.

Q: What are the benefits of using tinned copper conductors and UV-resistant jackets?

A: Tinned copper conductors ensure enhanced corrosion resistance and electrical conductivity, while UV-resistant jackets provide durability and longevity, even in outdoor or exposed installs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electrical Heat Tracing System For Pipes And Ta Category

Floor Heating System

Floor Heating System

Usage & Applications : Indoor heating for homes, offices, hotels, hospitals

Power Rating : 150300 W/m

Operating Temperature : 20C to 65C

Conductor : Single/Double Conductor

Rated Current : Up to 16A

Frequency : 50/60 Hz

Temprature Maintenance

Temprature Maintenance

Usage & Applications : Temperature maintenance and frost protection

Power Rating : 10W/m to 30W/m

Operating Temperature : 30C to +180C

Conductor : Copper

Rated Current : 16A

Frequency : 5060 Hz

Heat Up Pipes, Vessel And Tanks

Heat Up Pipes, Vessel And Tanks

Usage & Applications : Industrial Heating, Thermal Processing, Chemical Plants, Storage Vessels

Power Rating : 1 kW to 250 kW

Operating Temperature : 10C to 300C

Conductor : Stainless Steel/Alloy Tubes

Rated Current : As per Design

Frequency : 50 Hz / 60 Hz