Back to top

FLP Mannual Call Point (MCP)

FLP Mannual Call Point (MCP)
FLP Mannual Call Point (MCP)

FLP Mannual Call Point (MCP) Specification

  • Feature
  • Flameproof, Weatherproof, Corrosion Resistant
  • Power
  • Manual Activation, minimal standby power
  • Light Source
  • No internal light (non-illuminated MCP)
  • Voltage
  • 250V AC / 24V DC
  • Type
  • FLP Mannual Call Point (MCP)
  • Raw Material
  • Flameproof Die Cast Aluminum
  • Size
  • Standard as per IS/IEC 60947
  • Length
  • Standard (approx. 120 mm)
  • Width
  • Standard (approx. 120 mm)
  • Thickness
  • Approx. 2.5 mm enclosure wall
  • Density
  • Gram per cubic centimeter(g/cm3)
  • Thermal Conductivity
  • Low, suitable for hazardous locations
  • Water Absorption
  • None (FLP Enclosure)
  • Zone Classification
  • Suitable for Zone 1 & 2 hazardous areas
  • Actuation Method
  • Push Button (Break Glass type)
  • Ingress Protection
  • IP66
  • Visual Indication
  • Red Color easily visible
  • Cable Entry
  • 2 x 3/4" ET
  • Finish
  • Epoxy Powder Coated Red
  • Operating Temperature
  • -10C to +55C
  • Reset Facility
  • Manual Key Reset
  • Standards Compliance
  • IS/IEC 60079-1, IS/IEC 60947-5-1
  • Explosion Protection Marking
  • Ex d IIA/IIB
  • Application
  • Fire Alarm Systems in Chemical, Petrochemical, Oil & Gas Industries
  • Humidity Tolerance
  • Up to 95% RH Non-Condensing
  • Mounting Type
  • Wall Mounted
 
 

About FLP Mannual Call Point (MCP)



The FLP Manual Call Point (MCP) offers an incomparable level of safety for hazardous areas, making it a remarkable and cost-effective solution. Crafted from rarefied flameproof die-cast aluminum and finished in a striking epoxy powder-coated red, it ensures maximum visibility and reliability in chemical, petrochemical, and oil & gas fire alarm systems. Featuring instant checkout with a break glass push button, bargain value, and robust ingress protection (IP66), this wall-mounted MCP is tested to IS/IEC standards for ultimate protection. Its weatherproof, corrosion-resistant, and explosion-proof design guarantees safe, unparalleled performance, supporting manual key reset, all while maintaining a low expenditure and exceptional longevity for dealers and distributors across India.

Exceptional Safety for Hazardous Environments

FLP Manual Call Point (MCP) is used extensively in fire alarm systems within chemical, petrochemical, and oil & gas industries. It is engineered for actuation during emergencies by breaking glass and pressing the button, ensuring quick and reliable alerts. With features such as weatherproof, corrosion-resistant, and flameproof construction, along with a vivid red finish, this MCP offers optimum visibility and durability, establishing itself as the preferred choice in hazardous locations requiring advanced safety compliance and remarkable performance.


Domestic Market Reach and Order Arrangements

FLP Manual Call Point (MCP) is available across the main domestic markets of India, with shipment from major FOB ports ensuring estimated arrival within stipulated timelines. Dealers, wholesalers, and distributors can anticipate straightforward expenditure options, with flexible payment terms available to suit varied procurement needs. This MCP delivers both peace of mind and reliable arrival schedules, making budgeting and forecasting easy, while the supplier ensures a smooth ordering process for every client.


FAQ's of FLP Mannual Call Point (MCP):


Q: How does the FLP Manual Call Point (MCP) benefit hazardous area fire alarm systems?

A: The FLP MCP offers robust ingress protection (IP66), explosion-proof housing, and high visibility, making it ideal for prompt emergency activation in hazardous environments like chemical, petrochemical, and oil & gas industries.

Q: What is the process for activating the FLP MCP during emergencies?

A: Simply break the glass and press the push button. This instantly triggers the connected alarm system, allowing for immediate response to fire incidents.

Q: Where is the FLP Manual Call Point typically installed?

A: It is wall-mounted in high-risk industrial locations such as chemical plants, refineries, petrochemical facilities, and similar environments classified under Zone 1 and Zone 2 hazardous areas.

Q: When can I expect the FLP MCP to arrive after placing an order?

A: Order arrival depends on the shipment schedule from the designated FOB port, but dealers and customers in India can expect timely delivery in line with agreed estimates.

Q: What are the main features that make the FLP MCP stand out?

A: The FLP MCP features a rarefied flameproof aluminum body, weatherproof and corrosion-resistant construction, clear manual key reset, non-illuminated operation, and compliance with IS/IEC standards, ensuring remarkable reliability.

Q: How is the MCP reset after activation?

A: The unit is manually reset using a key provided with the MCP, ensuring that only authorized personnel can restore it to operational status after activation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Flame Proof Equipment Category

Flp Wall Clock

Flp Wall Clock

Feature : Silent Sweep Movement, Easy to Read Numbers, Lightweight

Raw Material : Plastic, Glass Front

Voltage : Battery Operated (1 AA, 1.5V)

Type : Other, Analog Wall Clock

Flexible Metal Conduit

Flexible Metal Conduit

Feature : Flameproof

Raw Material : Stainless Steel

Voltage : 440 VAC Volt (v)

Type : Other, Flexible Metal Conduit

Warranty : Yes

Water Absorption : No

Flameproof Junction Box

Flameproof Junction Box

Feature : Flameproof

Raw Material : Stainless Steel

Voltage : 440 VAC Volt (v)

Type : Other, Flameproof Junction Box

Warranty : Yes

Water Absorption : No